Powerware UPS Sidecar Powerware 9390 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Powerware UPS Sidecar Powerware 9390. Powerware UPS Sidecar Powerware 9390 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 124
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Powerware 9390 UPS Sidecar

Powerware 9390 UPS SidecarInstallation and Operation Manual®For use with 40–80 kVA and 100–160 kVA UPS Models

Page 2

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com1-41.2 Using This ManualThis manual

Page 3 - Table of Contents

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 480/480V UPS SIDECARMAINTENANCE BYPAS

Page 4 - TABLE OF CONTENTS

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 480/480V UPS SIDECARMAINTENANCE BYPAS

Page 5 - List of Figures

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 208/208V AND80/40, 80/50, 80/60, 80/8

Page 6 - LIST OF FIGURES

POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:120/100, 120/120 KVA, 480/480VMAINTENANCE BYPASS CONFIGURATION

Page 7 - Chapter 1 Introduction

POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:120/100, 120/120 KVA, 480/480VMAINTENANCE BYPASS CONFIGURATION

Page 8

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 208/208V AND80/40, 80/50, 80/60, 80/8

Page 9

POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:80/40, 80/50, 80/60, 80/80 KVA, 208/208V AND160/100, 160/120,

Page 10 - 1.2 Using This Manual

AC INPUTTO BYPASSPHASE CPHASE BPHASE ABIBPOWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:80/40, 80/50, 80/60,

Page 11 - Icon Description

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 480/480V UPS SIDECARPARALLEL REDUNDAN

Page 12 - SAVE THESE INSTRUCTIONS

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 208/208V AND40/20, 40/30, 40/40 KVA,

Page 13 - 1.6 Getting Help

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com1-51.3 Conventions Used in This Manu

Page 14 - INTRODUCTION

POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:40/20, 40/30, 40/40 KVA, 208/208V AND80/40, 80/50, 80/60, 80/8

Page 15 - Installation

AC INPUTFROM UPM 2PHASE CPHASE BPHASE AMOB 2POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:120/100, 120/120 K

Page 16 - EATON Powerware

POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:80/40, 80/50, 80/60, 80/80 KVA, 208/208V AND160/100, 160/120,

Page 17

POWER TERMINAL LOCATIONS062806C164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:80/40, 80/50, 80/60, 80/80 KVA, 208/208V AND160/100, 160/120,

Page 18 - Sidecar

1of4INTERFACE AND CONTROL WIRINGINSTALLATION NOTES ANDTERMINAL LOCATIONS063006DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---7INSTALLATION I

Page 19 - UPS Cabinet

063006DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:UPS SIDECAR TERMINAL TB1 FORPARALLEL REDUNDANTCONFIGURATIONS110TB1NOT USEDNOT USEDINTERFACE AND CON

Page 20 - UPM 1 UPM 2

INSTALLATION INFORMATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comA-66BackUp Control (Pull

Page 21 - INSTALLING THE UPS SIDECAR

INSTALLATION INFORMATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comA-67Module Output Breake

Page 22

1of4UPS SIDECAR DIM ENSIONS092107B164201546---8DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:FRONT VIEW RIGHT SIDE VIEWDimensions are in millimeters [in

Page 23

UPS SIDECAR DIM ENSIONS092107B164201546---8DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:TOP VIEWDimensions are in millimeters [inches]BOTTOM VIEW40 KV

Page 24

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com1-61.4 Safety WarningsIMPORTANT SAF

Page 25

UPS SIDECAR DIM ENSIONS031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:FRONT VIEW RIGHT SIDE VIEWDimensions are in millimeters [inches]120 KV A AND

Page 26 - 2.5 Initial Startup

UPS SIDECAR DIM ENSIONS031505A164201546---8DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:TOP VIEWDimensions are in millimeters [inches]BOTTOM VIEW120 KV

Page 27 - Installation Checklist

INSTALLATION INFORMATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comA-72This page intentiona

Page 29 - Operation

*164201586E*164201586 E

Page 30

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com1-71.6 Getting HelpIf help is needed

Page 31 - 3.1.1 UPS Mode

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com1-8This page intentionally left bla

Page 32 - UPS SIDECAR

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com1-1Section IInstallation

Page 33 - 4.2 Options

EATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com1-2

Page 34 - 4.3 Symbols

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-1Chapter 2 Installing the UPS Sidecar2.1 Insta

Page 35 - 4.4 UPS Sidecar Controls

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-23. If not already

Page 36 - Interlock Plate

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-3Front PanelFront Pa

Page 37

IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important instructions that you should follow during installation and mainten

Page 38

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-42.4 UPS Sidecar In

Page 39

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-51. Verify that the

Page 40

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-617. Align the hole

Page 41

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-72.4.2 Installing Li

Page 42

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-82.4.3 Standalone P

Page 43

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-92.4.4 Installing St

Page 44

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-102.4.5 Installing

Page 45 - RIB (if installed) CLOSED

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-11Installation Check

Page 46

INSTALLING THE UPS SIDECAREATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-12Notes____________

Page 47 - 4.8 Product Specifications

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com2-13Section IIOperation

Page 48

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comiTable of Contents1 Introduction 1-1...

Page 49 - Chapter 5 Warranty

EATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com2-14

Page 50 - WARRANTY

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com3-1Chapter 3 Understanding OperationThe UPS Side

Page 51 - Installation Information

UNDERSTANDING OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com3-23.1.2 Maintenance Byp

Page 52 - 80 kVA UPS

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-1Chapter 4 UPS Sidecar Features, Controls, and

Page 53 - 160 kVA UPS

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 54

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-3

Page 55

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 56 - “A” O R “ B ”

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-5

Page 57 - DIGITAT“A”

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 58 - AT “B” OR HIGHER

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-7

Page 59

TABLE OF CONTENTSEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.comii4.5 UPS Sidecar Operation –

Page 60

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 61 - 164201546---3 6 of 11

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-9

Page 62 - 164201546---3 7 of 11

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 63 - 164201546---3 8 of 11

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-1

Page 64

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 65

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-1

Page 66 - (1+1 CONFIGURATION)

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 67 - 5 of 11, and 9 of 11

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com4-1

Page 68

UPS SIDECAR FEATURES, CONTROLS, AND OPERATIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com4-

Page 69

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com5-1Chapter 5 WarrantyLimited Factory WarrantyThr

Page 70

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comiiiList of FiguresFigure 1-1. Powerware 9390 UPS

Page 71

WARRANTYEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com5-2This page intentionally left blank.

Page 72

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.comA-1Appendix AFigurInstallation InformationThe in

Page 73

1of3031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:BATTERY CABINET80 kVA UPSCABINET164201546---1TYPICAL MAINTENANCE B YPASS ORSTANDALONE PARALLEL

Page 74

031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---1BATTERY CABINET160 kVA UPSCABINETTYPICAL POWERWARE 9390 UPS SYSTEMWITH UPS SIDECAR2of3

Page 75

031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---1TYPICAL POWERWARE 9390 UPS SYSTEMWITH UPS SIDECARBATTERY CABINET80 kVA UPSCABINET 180

Page 76

DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---2 1 of 1PHYSICAL FEATURES AND REQUIREMENTS031505AINSTALLATION INFORMATIONEATON Powerware®9390

Page 77 - 80 KV A UPS

UPS SIDECAR ONELINE DRAWINGS062806CDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:MAINTENANCE BYPASS CONFIGURATION80/40, 80/50, 80/60 AND 80/80 kVA,208/2

Page 78 - 160 KV A UPS

UPS SIDECAR ONELINE DRAWINGS062806BDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:MAINTENANCE BYPASS CONFIGURATION120/100 AND 120/120 kVA, 480/480V160/10

Page 79 - RIGHT SIDE VIEW

UPS SIDECAR ONELINE DRAWINGS062806BDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:K1K5K3Po werware 9390 UPS CABINETUPS SidecarMAINTENANCEBYPASS SWITCH(MB

Page 80

UPS SIDECAR ONELINE DRAWINGS062806BDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:K1K5K3Po werware 9390 UPS CABINETUPS SidecarMAINTENANCEBYPASS SWITCH(MB

Page 81

LIST OF FIGURESEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.comivThis page intentionally left b

Page 82

UPS SIDECAR ONELINE DRAWINGS062806BMAINTENANCE BYPASS WITH BIB CONFIGURATION40/20, 40/30, 40/40, 80/40, 80/50, 80/60, AND 80/80 kVA,208/208V AND 480/4

Page 83

UPS SIDECAR ONELINE DRAWINGS062806BMAINTENANCE BYPASS WITH BIB CONFIGURATION120/100 AND 120/120 kVA, 480/480V160/100, 160/120, AND 160/160 kVA, 480/48

Page 84

UPS ONLINE ONELINE DRAWINGS062806BMAINTENANCE BYPASS WITH BIB CONFIGURATION120/100 AND 120/120 kVA, 480/480VWITH UPS SERIAL NUMBER SEVENTH DIGIT AT “B

Page 85

UPS SIDECAR ONELINE DRAWINGS062806BMAINTENANCE BYPASS WITH BIB CONFIGURATION160/100, 160/120, and 160/160 kVA, 480/480VWITH UPS SERIAL NUMBER SEVENTH

Page 86

UPS SIDECAR ONELINE DRAWINGS092107CMAINTENANCE B YPASS WITH BIB AND RIB40/20, 40/30, 40/40, 208/208V,120/100, 120/120 kVA, 480/480V and160/100, 160/12

Page 87

UPS SIDECAR ONELINE DRAWINGS092107CMAINTENANCE B YPASS WITH BIB AND RIB80/40, 80/50, 80/60, 80/80 kVA, 480/480V,DESCRIPTION:DATE:DRAWING NO: SHEET:REV

Page 88

DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:031505AOUTPUT TOCRITICAL LOADE4. E5FUSEK5STATICSWITCHFUSEK3FUSEBATTERYCONVERTERRECTIFIERINVERTERK1UPM 2E1E

Page 89

1of10POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:D164201546---4INSTALLATION INFORMATIONEATON Powerware®9390 UPS S

Page 90

POWER WIRING INSTALLATION NOTES061507DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:D164201546---4 2 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 91

POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:D164201546---4 3 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 92 - 164201546---6 13 of 34

EATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com1-1Chapter 1 IntroductionThe Eaton®Powerware®939

Page 93 - 164201546---6 14 of 34

POWER WIRING INSTALLATION NOTES061507DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:C164201546---4 4 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 94 - 164201546---6 15 of 34

POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:D164201546---4 5 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 95

POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:D164201546---4 6 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 96

POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:E164201546---4 7 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 97

POWER WIRING INSTALLATION NOTES092107DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:E164201546---4 8 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 98

POWER WIRING INSTALLATION NOTES062206DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:C164201546---4 9 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 99

POWER WIRING INSTALLATION NOTES063006B164201546---4DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:10 of 10INSTALLATION INFORMATIONEATON Powerware®9390 UP

Page 100 - 21 of 34

1of3CONDUIT AND WIRE ENTRY LOCATIONS031505A164201546---5DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:TOP VIEWBOTTOM VIEWUPS SIDECAR BOTTOM ENTRYCONDUIT

Page 101 - 22 of 34

CONDUIT AND WIRE ENTRY LOCATIONS031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:TOP VIEWBOTTOM VIEWUPS SIDECAR BOTTOM ENTRYCONDUIT LANDING FOR ACIN

Page 102 - 23 of 34

CONDUIT AND WIRE ENTRY LOCATIONS031505ADESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---5INTER-CABINET WIRING ACCESS KNOCKOUTS.REMOVE KNOCKOUTS

Page 103 - 24 of 34

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation M anual S 164201586 Rev E www.powerware.com1-2Figure 1-1. Powerware 9390 UPS (

Page 104 - 25 of 34

1of34POWER TERMINAL LOCATIONS092107D164201546---6DESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be remov

Page 105 - 26 of 34

POWER TERMINAL LOCATIONS092107DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to gain access

Page 106 - 27 of 34

POWER TERMINAL LOCATIONS092107DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE 1. Metal shields covering wiringterminals must be removed toaccess ter

Page 107 - 28 of 34

POWER TERMINAL LOCATIONS092107DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiringterminals must be removed toaccess termin

Page 108 - 29 of 34

POWER TERMINAL LOCATIONS092107DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE 1. Metal shields covering wiringterminals must be removed toaccess ter

Page 109 - 30 of 34

POWER TERMINAL LOCATIONS062806CDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiringterminals must be removed toaccess termin

Page 110 - 31 of 34

POWER TERMINAL LOCATIONS092107DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6MAINTENANCEBYP ASS SWITCH (MBP)MAINTENANCEISOLATION SWITCH (MI

Page 111 - 32 of 34

POWER TERMINAL LOCATIONS062806CDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6MAINTENANCEBYP ASS SWITCH (MBP)MAINTENANCEISOLATION SWITCH (MI

Page 112 - 33 of 34

POWER TERMINAL LOCATIONS062806CDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6MAINTENANCEBYP ASS SWITCH (MBP)(SEE SHEET 27 of 34FOR DETAILS)

Page 113 - SLB OUTPUT TERMINAL DETAIL

POWER TERMINAL LOCATIONS062806CDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6MAINTENANCEBYP ASS SWITCH (MBP)(SEE SHEET 28 of 34FOR DETAILS)

Page 114 - INSTALLATION INFORMATION

INTRODUCTIONEATON Powerware®9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com1-3Figure 1-2. Powerware 9390 UPS (1

Page 115 - CONFIGURATIONS

POWER TERMINAL LOCATIONS092107EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to access termi

Page 116 - (PULL CHAIN) WIRING

POWER TERMINAL LOCATIONS092107EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to access termi

Page 117 - MOB MONITORING WIRING

POWER TERMINAL LOCATIONS092107EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to access termi

Page 118 - FRONT VIEW RIGHT SIDE VIEW

POWER TERMINAL LOCATIONS092107EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to access termi

Page 119 - WITH SIDECAR

POWER TERMINAL LOCATIONS063006DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:NOTE Metal shields covering wiring terminalsmust be removed to access termi

Page 120

POWER TERMINAL LOCATIONS092107EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6(SEE SHEET 31 of 34FOR DETAILS)40/20, 40/30, 40/40 KVA, 208/20

Page 121 - 120 KV A AND 160 KVA UPS

POWER TERMINAL LOCATIONS061507EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6(SEE SHEET 31 of 34FOR DETAILS)80/40, 80/50, 80/60, 80/80 KVA,

Page 122

POWER TERMINAL LOCATIONS063006EDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6(SEE SHEET 32 of 34FOR DETAILS)120/100, 120/120 KVA, 480/480VP

Page 123

POWER TERMINAL LOCATIONS063006DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6(SEE SHEET 33 of 34FOR DETAILS)80/40, 80/50, 80/60, 80/80 KVA,

Page 124 - *164201586E*

POWER TERMINAL LOCATIONS063006DDESCRIPTION:DATE:DRAWING NO: SHEET:REVISION:164201546---6(SEE SHEET 33 of 34FOR DETAILS)PARALLEL REDUNDANT CONFIGURATIO

Commentaires sur ces manuels

Pas de commentaire