Powerware Tool Storage 9155 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Alimentations sans interruption (UPS) Powerware Tool Storage 9155. Powerware Tool Storage 9155 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 66
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Powerware 9155 Parallel UPS
8–15 kVA
User’s Guide
®
Vue de la page 0
1 2 3 4 5 6 ... 65 66

Résumé du contenu

Page 1 - User’s Guide

Powerware 9155 Parallel UPS8–15 kVAUser’s Guide®

Page 2 - Class A EMC Statements

SAFETY WARNINGSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com4Consignes de SécuritéCONSIGNES DE SÉCURIT

Page 3

SAFETY WARNINGSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com5Advertencias de SeguridadINSTRUCCIONES DE

Page 4 - Special Symbols

SAFETY WARNINGSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com6

Page 5 - Table of Contents

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com7Chapter 3 UPS SetupThis chapter describes:S Equipment in

Page 6 - TABLE OF CONTENTS

UPS SETUPEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com8Floor LoadingWhen planning the installation, co

Page 7 - Chapter 1 Introduction

UPS SETUPEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com9Unloading the Cabinet(s)The following tools are

Page 8 - INTRODUCTION

UPS SETUPEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com103. Remove the front cover from the bottom cabi

Page 9 - Chapter 2 Safety Warnings

UPS SETUPEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com11NOTE Be sure to support the front and back of

Page 10 - ATTENTION!

UPS SETUPEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com12

Page 11 - PRECAUCIÓN

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com13Chapter 4 Parallel InstallationThe Powerware 9155 has t

Page 12 - SAFETY WARNINGS

Class A EMC StatementsFCC Part 15NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant topart

Page 13 - Chapter 3 UPS Setup

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com14WARNINGOnly qualified service pers

Page 14 - Clearances

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com155. Remove the parallel tie cabinet

Page 15 - Unloading the Cabinet(s)

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com167. Punch holes for the conduit (AC

Page 16 - UPS SETUP

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com1710. Verify that each UPS battery c

Page 17 - Figure 5. Removing the Pallet

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com18NOTE Input neutral must be wired f

Page 18

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com1913. Hardwire the output terminatio

Page 19 - EATON Powerware

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com2015. Hardwire the load to the paral

Page 20 - PARALLEL INSTALLATION

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com2116. Wire the AC input to the bypas

Page 21 - Figure 7)

PARALLEL INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com22Figure 14. Parallel Wiring Diagram

Page 22

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com23Chapter 5 Installing OptionsThis section describes the

Page 23

Requesting a Declaration of ConformityUnits that are labeled with a CE mark comply with the following harmonized standards and EU directives:S Harmoni

Page 24 - Figure 10. UPS Terminal Block

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com24Powerware Hot Sync CAN Bridge CardThe

Page 25

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com252. If you ordered a factory-configure

Page 26 - Figure 12. Load Connections

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com26NOTE If you are installing another X-

Page 27

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com27UPS #1 UPS #2 UPS #3Figure 19. CAN Br

Page 28

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com288. Secure the Powerware Hot Sync CAN

Page 29 - Chapter 5 Installing Options

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com2911. Reinstall the front covers, start

Page 30 - Plug-in Terminal Block

INSTALLING OPTIONSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com30

Page 31 - Jumper J7 - Pins 2 and 3

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com31Chapter 6 Stabilizing the CabinetNOTE For seismic insta

Page 32 - INSTALLING OPTIONS

STABILIZING THE CABINETEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com324. Continue to one of the follow

Page 33 - UPS #1 UPS #2 UPS #3

STABILIZING THE CABINETEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com33M4 ScrewsFigure 24. Stabilizing

Page 34

Special SymbolsThe following are examples of symbols used on the UPS or accessories to alert you to importantinformation:RISK OF ELECTRIC SHOCK - Indi

Page 35

STABILIZING THE CABINETEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com34

Page 36

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com35Chapter 7 Extended Battery Module InstallationNOTE A ma

Page 37

EXTENDED BATTERY MODULE INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com36UPS Battery Connect

Page 38 - M4 Screws

EXTENDED BATTERY MODULE INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com378. Remove the top f

Page 39

EXTENDED BATTERY MODULE INSTALLATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com38

Page 40 - STABILIZING THE CABINET

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com39Chapter 8 OperationThis chapter contains information on

Page 41

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com40The following table shows the indicator status

Page 42

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com41The following table shows the basic menu struc

Page 43 - Front Ground Strap

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com42User SettingsThe following table displays the

Page 44

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com43Table 4. User Settings (continued)Default Sett

Page 45 - Chapter 8 Operation

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.comiTable of Contents1 Introduction 1...

Page 46 - Display Functions

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com44Table 4. User Settings (continued)Default Sett

Page 47 - OPERATION

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com45Parallel UPS StartupWARNINGOnly qualified serv

Page 48 - User Settings

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com466. Configure the UPS for parallel operation th

Page 49

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com479. Shut down each UPS:S Press the button on th

Page 50

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com4817. Select the System On option; press t he bu

Page 51 - Parallel UPS Startup

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com49Configuring t he UPS for EBMsNOTE Each UPS in

Page 52

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com50Parallel System ShutdownTo remove power to the

Page 53

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com51Individual UPS ShutdownTo shut down a single U

Page 54

OPERATIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com52Restarting the Parallel SystemTo restart the p

Page 55 - Configuring t he UPS for EBMs

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com53Chapter 9 Parallel BypassTo switch the parallel UPS to

Page 56 - Parallel System Shutdown

TABLE OF CONTENTSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.comii

Page 57 - Individual UPS Shutdown

PARALLEL BYPASSEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com54To return to Normal mode from maintenanc

Page 58

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com55Chapter 10 TroubleshootingThe Powerware 9155 is designe

Page 59 - Chapter 9 Parallel Bypass

TROUBLESHOOTINGEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com56ActionPossible CauseAlarm or ConditionOv

Page 60 - PARALLEL BYPASS

TROUBLESHOOTINGEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com57ActionPossible CauseAlarm or ConditionCh

Page 61 - Chapter 10 Troubleshooting

TROUBLESHOOTINGEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com58Service and SupportIf you have any quest

Page 63 - Silencing the Alarm

*164201592C*164201592 C

Page 64 - Service and Support

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com1Chapter 1 IntroductionA parallel system with up to three

Page 65

INTRODUCTIONEATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com2

Page 66 - *164201592C*

EATON Powerware®9155 Parallel UPS (8–15 kVA) User’s Guide S 164201592 Rev C www.powerware.com3Chapter 2 Safety WarningsIMPORTANT SAFETY INSTRUCTIONSSA